Manufacturing Solar in Adelaide
Cut daytime machinery costs. Systems up to 1 MW now earn STCs.
Factories and engineering workshops use most of their power in daylight, running compressors, CNC machines, welders and extraction on weekday shifts. Energy Buster designs commercial solar around that load, the roof and the switchboard, and checks the rest of the bill while we’re there.
Solar for Manufacturing Sites: The Short Answer
Manufacturing projects delivered by our engineering team range from 15 kW to 100 kW, sized to weekday daytime load rather than roof area. Across six of those projects, estimated paybacks range from 3.1 to 4.0 years, often as part of a package with LED lighting and power factor correction. What differs for factories: three-phase machinery loads, demand charges and older roof structures. Systems up to 1 MW now earn STCs, so larger sites can size past 100 kW.
Why Manufacturing Sites Suit Solar
A factory’s load profile is one of the best matches for solar generation. The details still need checking site by site.
Production Runs in Daylight
Day shifts line up with solar generation, so a well-sized system is used on site instead of exported at a low feed-in rate. Sites with compressors, extraction or refrigeration running all day use even more of it.
Large, Low-Pitched Metal Roofs
Industrial buildings in areas like Athol Park, Royal Park and Wingfield usually have broad metal roofs with few obstructions. Older roofs need their sheeting, purlins and fixings checked before a large array goes on.
Three-Phase Machinery and Power Factor
Motors, welders and compressors draw heavily on three-phase supply and often cause poor power factor, which can push up network charges. Solar doesn’t fix that on its own, which is why A1 Anco Engineering’s solution added two 50 kVAr power factor correction units alongside the solar.
Energy Charges vs Demand Charges
Solar cuts the energy you buy in daylight. It can’t be relied on to lower a demand charge set by a machinery start-up on a cloudy morning. We read both sides of the bill before recommending a system size, and treat tariff review as part of the job.
Case Study: A1 Anco Engineering, Athol Park
A1 Anco Engineering is an Australian-owned machining and manufacturing business with more than 30 years’ experience, supplying customers in Adelaide and overseas.
Energy Buster delivered a four-part solution across the site’s two electricity meters: a 15 kW solar system, an LED lighting upgrade, two 50 kVAr power factor correction units and a tariff review. Handling both meters together meant a tariff change on one meter didn’t dilute the savings.
Commercial Solar Incentives Now
For manufacturers: sites that were previously held to 100 kW to stay inside the scheme can now size to their actual daytime load, up to 1 MW, and still earn STCs.
Manufacturing Solar Sizes From Real Projects
These are South Australian manufacturing projects delivered by Energy Buster and our sister company Sustainable Savings, which shares the same engineering team. They show the range of system sizes, not fixed packages.
| Project | Business | System | Est. payback |
|---|---|---|---|
| A1 Anco Engineering, Athol Park | Machining and engineering | 15 kW, plus LED and power factor correction | 3.3 years |
| HR Products, Royal Park | Irrigation equipment manufacturer | 60 kW in two 30 kW stages, plus LED | 3.2 years |
| Minijumbuk, Naracoorte | Wool bedding manufacturer | 78.5 kW, plus LED | 3.6 years |
| Haircare Australia, Marleston | Hair care manufacturer and distributor | 100 kW, solar only | 3.1 years |
| Quality Always, Dry Creek | Wool textile manufacturer | 100 kW, plus LED | 3.4 years |
| Quality Plastics & Tooling, Wingfield | Plastic components manufacturer | 100 kW | 4.0 years |
Paybacks are the published estimates for each whole project, and several projects include work beyond solar. Your payback depends on your daytime load, tariff, roof and the equipment selected. For sizing references, see our 30 kW, 50 kW and 100 kW system pages. For larger projects and the full range of sizes we have delivered, see our commercial solar system sizes.
Design, Approvals and Installation
Roof and Structure
We check roof sheeting, purlins, fixings, corrosion and shading. On large or older roofs, a structural engineer confirms the load before the design is final.
Three-Phase Supply and Switchboard
Commercial systems connect to three-phase supply at the main switchboard. We check its capacity, protection and space for new equipment, and include any upgrade in the proposal.
Network Connection and Export Limits
Systems above 30 kVA on a low-voltage connection must meet SA Power Networks’ TS132 technical standard and go through its approval process. Export limits may apply, and we design around them.
Installing Without Stopping Work
Rooftop work happens while the site operates. The switchboard connection needs a short planned shutdown, which we schedule around your operating hours.
Battery Option
Where evening load, export limits or backup needs make storage worth considering, we model a battery separately so you can see whether it pays its way.
Monitoring
Every system is handed over with monitoring, so you can compare generation and site consumption and spot a fault early.
For manufacturers: tell us about shift patterns, planned shutdowns and any new machinery on the way. We time the switchboard work around production and size the system for the load you’ll have, not just the load you have today.
Why Choose Energy Buster Panels
From Bill Review to Switch-On
1. Bill and Data Review
We review your bills and, where available, interval data from your meter.
2. Site Assessment
Roof, structure, shading, access and switchboard inspection.
3. Design and Proposal
System layout, equipment, savings modelling and a written proposal.
4. Network Approval
Connection application to SA Power Networks.
5. Equipment and Scheduling
Equipment ordered, and installation dates set around your operations.
6. Installation
Mounting, panels, inverters and cabling while the site keeps operating.
7. Connection and Commissioning
Planned switchboard shutdown, testing and switch-on.
8. Handover and STCs
Monitoring set-up, documentation and STC paperwork.
Ways to Pay for Commercial Solar
How you pay for a system changes who owns it, how it’s treated for tax and how quickly you see the saving. The common options are:
Each option has different tax, ownership and cash-flow implications. Talk to your accountant or financier about what suits your organisation.
More Manufacturing Proof
Read independent customer reviews of Energy Buster on SolarQuotes, or browse all case studies.
Solar for other industries: food processing solar · supermarket solar · all commercial solar in Adelaide
Manufacturing Solar FAQs
Send Us a Quarterly Bill for a Manufacturing Bill Check
Send us a recent quarterly bill and we’ll look at the parts that matter for a factory:
- How much of your energy is used in daylight on working days
- Demand charges and power factor
- Whether your tariff still suits how the site operates
- A solar size range matched to that load
Prefer to talk? Call (08) 7120 6377.



